All explosives manufacturing buildings shall be located one from the other and from other buildings on explosives manufacturing plants in which persons are regularly employed, and all magazines shall be located from factory buildings and buildings on explosives plants in which persons are regularly employed, in conformity with the intraexplosives plant quantity and distance table below set forth:
|
|
|
|
|
|
EXPLOSIVES
|
|
||||
Pounds
Over
|
Pounds
Not Over
|
Distance
Feet
|
|||
|
|||||
|
|
Separate
Building or
Within
Substantial
Dividing Walls
|
|||
. . . .
|
|
10
|
|
|
|
10
|
|
25
|
|
40
|
|
25
|
|
50
|
|
60
|
|
50
|
|
100
|
|
80
|
|
100
|
|
200
|
|
100
|
|
200
|
|
300
|
|
120
|
|
300
|
|
400
|
|
130
|
|
400
|
|
500
|
|
140
|
|
500
|
|
750
|
|
160
|
|
750
|
|
1,000
|
|
180
|
|
1,000
|
|
1,500
|
|
210
|
|
1,500
|
|
2,000
|
|
230
|
|
2,000
|
|
3,000
|
|
260
|
|
3,000
|
|
4,000
|
|
280
|
|
4,000
|
|
5,000
|
|
300
|
|
5,000
|
|
6,000
|
|
320
|
|
6,000
|
|
7,000
|
|
340
|
|
7,000
|
|
8,000
|
|
360
|
|
8,000
|
|
9,000
|
|
380
|
|
9,000
|
|
10,000
|
|
400
|
|
10,000
|
|
12,500
|
|
420
|
|
12,500
|
|
15,000
|
|
450
|
|
15,000
|
|
17,500
|
|
470
|
|
17,500
|
|
20,000
|
|
490
|
|
20,000
|
|
25,000
|
|
530
|
|
25,000
|
|
30,000
|
|
560
|
|
30,000
|
|
35,000
|
|
590
|
|
35,000
|
|
40,000
|
|
620
|
|
40,000
|
|
45,000
|
|
640
|
|
45,000
|
|
50,000
|
|
660
|
|
50,000
|
|
55,000
|
|
680
|
|
55,000
|
|
60,000
|
|
700
|
|
60,000
|
|
65,000
|
|
720
|
|
65,000
|
|
70,000
|
|
740
|
|
70,000
|
|
75,000
|
|
770
|
|
75,000
|
|
80,000
|
|
780
|
|
80,000
|
|
85,000
|
|
790
|
|
85,000
|
|
90,000
|
|
800
|
|
90,000
|
|
95,000
|
|
820
|
|
95,000
|
|
100,000
|
|
830
|
|
100,000
|
|
125,000
|
|
900
|
|
125,000
|
|
150,000
|
|
950
|
|
150,000
|
|
175,000
|
|
1,000
|
|
175,000
|
|
200,000
|
|
1,050
|
|
200,000
|
|
225,000
|
|
1,100
|
|
225,000
|
|
250,000
|
|
1,150
|
|
[ 1972 ex.s. c 88 § 8; 1931 c 111 § 5; RRS § 5440-5.]