The energy and water (in the case of faucets, showerheads, water closets, and urinals) conservation standards for the covered product classes are:

Ask a business law question, get an answer ASAP!
Thousands of highly rated, verified business lawyers.
Click here to chat with a lawyer about your rights.

(a) Refrigerators/refrigerator-freezers/freezers. These standards do not apply to refrigerators and refrigerator-freezers with total refrigerated volume exceeding 39 cubic feet (1104 liters) or freezers with total refrigerated volume exceeding 30 cubic feet (850 liters). The energy standards as determined by the equations of the following table(s) shall be rounded off to the nearest kWh per year. If the equation calculation is halfway between the nearest two kWh per year values, the standard shall be rounded up to the higher of these values.

The following standards remain in effect from July 1, 2001 until September 15, 2014:

Product classEnergy standard equations for maximum energy use
(kWh/yr)
1. Refrigerators and refrigerator-freezers with manual defrost8.82AV + 248.4
0.31av + 248.4
2. Refrigerator-freezers—partial automatic defrost8.82AV + 248.4
0.31av + 248.4
3. Refrigerator-freezers—automatic defrost with top-mounted freezer without through-the-door ice service and all-refrigerator—automatic defrost9.80AV + 276.0
0.35av + 276.0
4. Refrigerator-freezers—automatic defrost with side-mounted freezer without through-the-door ice service4.91AV + 507.5
0.17av + 507.5
5. Refrigerator-freezers—automatic defrost with bottom-mounted freezer without through-the-door ice service4.60AV + 459.0
0.16av + 459.0
6. Refrigerator-freezers—automatic defrost with top-mounted freezer with through-the-door ice service10.20AV + 356.0
0.36av + 356.0
7. Refrigerator-freezers—automatic defrost with side-mounted freezer with through-the-door ice service10.10AV + 406.0
0.36av + 406.0
8. Upright freezers with manual defrost7.55AV + 258.3
0.27av + 258.3
9. Upright freezers with automatic defrost12.43AV + 326.1
0.44av + 326.1
10. Chest freezers and all other freezers except compact freezers9.88AV + 143.7
0.35av + 143.7
11. Compact refrigerators and refrigerator-freezers with manual defrost10.70AV + 299.0
0.38av + 299.0
12. Compact refrigerator-freezer—partial automatic defrost7.00AV + 398.0
0.25av + 398.0
13. Compact refrigerator-freezers—automatic defrost with top-mounted freezer and compact all-refrigerator—automatic defrost12.70AV + 355.0
0.45av + 355.0
14. Compact refrigerator-freezers—automatic defrost with side-mounted freezer7.60AV + 501.0
0.27av + 501.0
15. Compact refrigerator-freezers—automatic defrost with bottom-mounted freezer13.10AV + 367.0
0.46av + 367.0
16. Compact upright freezers with manual defrost9.78AV + 250.8
0.35av + 250.8
17. Compact upright freezers with automatic defrost11.40AV + 391.0
0.40av + 391.0
18. Compact chest freezers10.45AV + 152.0
0.37av + 152.0

AV: Adjusted Volume in ft3; av: Adjusted Volume in liters (L).

The following standards apply to products manufactured starting on September 15, 2014:


Product class
Equations for maximum energy use
(kWh/yr)
Based on AV (ft3)Based on av (L)
1. Refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost7.99AV + 225.00.282av + 225.0
1A. All-refrigerators—manual defrost6.79AV + 193.60.240av + 193.6
2. Refrigerator-freezers—partial automatic defrost7.99AV + 225.00.282av + 225.0
3. Refrigerator-freezers—automatic defrost with top-mounted freezer without an automatic icemaker8.07AV + 233.70.285av + 233.7
3-BI. Built-in refrigerator-freezer—automatic defrost with top-mounted freezer without an automatic icemaker9.15AV + 264.90.323av + 264.9
3I. Refrigerator-freezers—automatic defrost with top-mounted freezer with an automatic icemaker without through-the-door ice service8.07AV + 317.70.285av + 317.7
3I-BI. Built-in refrigerator-freezers—automatic defrost with top-mounted freezer with an automatic icemaker without through-the-door ice service9.15AV + 348.90.323av + 348.9
3A. All-refrigerators—automatic defrost7.07AV + 201.60.250av + 201.6
3A-BI. Built-in All-refrigerators—automatic defrost8.02AV + 228.50.283av + 228.5
4. Refrigerator-freezers—automatic defrost with side-mounted freezer without an automatic icemaker8.51AV + 297.80.301av + 297.8
4-BI. Built-In Refrigerator-freezers—automatic defrost with side-mounted freezer without an automatic icemaker10.22AV + 357.40.361av + 357.4
4I. Refrigerator-freezers—automatic defrost with side-mounted freezer with an automatic icemaker without through-the-door ice service8.51AV + 381.80.301av + 381.8
4I-BI. Built-In Refrigerator-freezers—automatic defrost with side-mounted freezer with an automatic icemaker without through-the-door ice service10.22AV + 441.40.361av + 441.4
5. Refrigerator-freezers—automatic defrost with bottom-mounted freezer without an automatic icemaker8.85AV + 317.00.312av + 317.0
5-BI. Built-In Refrigerator-freezers—automatic defrost with bottom-mounted freezer without an automatic icemaker9.40AV + 336.90.332av + 336.9
5I. Refrigerator-freezers—automatic defrost with bottom-mounted freezer with an automatic icemaker without through-the-door ice service8.85AV + 401.00.312av + 401.0
5I-BI. Built-In Refrigerator-freezers—automatic defrost with bottom-mounted freezer with an automatic icemaker without through-the-door ice service9.40AV + 420.90.332av + 420.9
5A. Refrigerator-freezer—automatic defrost with bottom-mounted freezer with through-the-door ice service9.25AV + 475.40.327av + 475.4
5A-BI. Built-in refrigerator-freezer—automatic defrost with bottom-mounted freezer with through-the-door ice service9.83AV + 499.90.347av + 499.9
6. Refrigerator-freezers—automatic defrost with top-mounted freezer with through-the-door ice service8.40AV + 385.40.297av + 385.4
7. Refrigerator-freezers—automatic defrost with side-mounted freezer with through-the-door ice service8.54AV + 432.80.302av + 432.8
7-BI. Built-In Refrigerator-freezers—automatic defrost with side-mounted freezer with through-the-door ice service10.25AV + 502.60.362av + 502.6
8. Upright freezers with manual defrost5.57AV + 193.70.197av + 193.7
9. Upright freezers with automatic defrost without an automatic icemaker8.62AV + 228.30.305av + 228.3
9I. Upright freezers with automatic defrost with an automatic icemaker8.62AV + 312.30.305av + 312.3
9-BI. Built-In Upright freezers with automatic defrost without an automatic icemaker9.86AV + 260.90.348av + 260.9
9I-BI. Built-in upright freezers with automatic defrost with an automatic icemaker9.86AV + 344.90.348av + 344.9
10. Chest freezers and all other freezers except compact freezers7.29AV + 107.80.257av + 107.8
10A. Chest freezers with automatic defrost10.24AV + 148.10.362av + 148.1
11. Compact refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost9.03AV + 252.30.319av + 252.3
11A.Compact all-refrigerators—manual defrost7.84AV + 219.10.277av + 219.1
12. Compact refrigerator-freezers—partial automatic defrost5.91AV + 335.80.209av + 335.8
13. Compact refrigerator-freezers—automatic defrost with top-mounted freezer11.80AV + 339.20.417av + 339.2
13I. Compact refrigerator-freezers—automatic defrost with top-mounted freezer with an automatic icemaker11.80AV + 423.20.417av + 423.2
13A. Compact all-refrigerators—automatic defrost9.17AV + 259.30.324av + 259.3
14. Compact refrigerator-freezers—automatic defrost with side-mounted freezer6.82AV + 456.90.241av + 456.9
14I. Compact refrigerator-freezers—automatic defrost with side-mounted freezer with an automatic icemaker6.82AV + 540.90.241av + 540.9
15. Compact refrigerator-freezers—automatic defrost with bottom-mounted freezer11.80AV + 339.20.417av + 339.2
15I. Compact refrigerator-freezers—automatic defrost with bottom-mounted freezer with an automatic icemaker11.80AV + 423.20.417av + 423.2
16. Compact upright freezers with manual defrost8.65AV + 225.70.306av + 225.7
17. Compact upright freezers with automatic defrost10.17AV + 351.90.359av + 351.9
18. Compact chest freezers9.25AV + 136.80.327av + 136.8

AV = Total adjusted volume, expressed in ft3, as determined in appendices A and B of subpart B of this part.

av = Total adjusted volume, expressed in Liters.

(b) Room air conditioners. (1) The following standards remain in effect from June 1, 2014, until May 26, 2026:

Table 3 to Paragraph (b)

Equipment classCombined energy
efficiency ratio
1. Without reverse cycle, with louvered sides, and with a certified cooling capacity 1 less than 6,000 Btu/h11.0
2. Without reverse cycle, with louvered sides and with a certified cooling capacity of 6,000 to 7,999 Btu/h11.0
3. Without reverse cycle, with louvered sides and with a certified cooling capacity of 8,000 to 13,999 Btu/h10.9
4. Without reverse cycle, with louvered sides and with a certified cooling capacity of 14,000 to 19,999 Btu/h10.7
5a. Without reverse cycle, with louvered sides and with a certified cooling capacity of 20,000 Btu/h to 27,999 Btu/h9.4
5b. Without reverse cycle, with louvered sides and with a certified cooling capacity of 28,000 Btu/h or more9.0
6. Without reverse cycle, without louvered sides, and with a certified cooling capacity less than 6,000 Btu/h10.0
7. Without reverse cycle, without louvered sides and with a certified cooling capacity of 6,000 to 7,999 Btu/h10.0
8a. Without reverse cycle, without louvered sides and with a certified cooling capacity of 8,000 to 10,999 Btu/h9.6
8b. Without reverse cycle, without louvered sides and with a certified cooling capacity of 11,000 to 13,999 Btu/h9.5
9. Without reverse cycle, without louvered sides and with a certified cooling capacity of 14,000 to 19,999 Btu/h9.3
10. Without reverse cycle, without louvered sides and with a certified cooling capacity of 20,000 Btu/h or more9.4
11. With reverse cycle, with louvered sides, and with a certified cooling capacity less than 20,000 Btu/h9.8
12. With reverse cycle, without louvered sides, and with a certified cooling capacity less than 14,000 Btu/h9.3
13. With reverse cycle, with louvered sides, and with a certified cooling capacity of 20,000 Btu/h or more9.3
14. With reverse cycle, without louvered sides, and with a certified cooling capacity of 14,000 Btu/h or more8.7
15. Casement-Only9.5
16. Casement-Slider10.4

1 The certified cooling capacity is determined by the manufacturer in accordance with 10 CFR 429.15(a)(3).

(2) The following standards apply to products manufactured starting May 26, 2026:

Table 4 to Paragraph (b)(2)

Equipment classCombined energy
efficiency ratio
1. Without reverse cycle, with louvered sides, and with a certified cooling capacity 1 less than 6,000 Btu/h13.1
2. Without reverse cycle, with louvered sides and with a certified cooling capacity of 6,000 to 7,900 Btu/h13.7
3. Without reverse cycle, with louvered sides and with a certified cooling capacity of 8,000 to 13,900 Btu/h16.0
4. Without reverse cycle, with louvered sides and with a certified cooling capacity of 14,000 to 19,900 Btu/h16.0
5a. Without reverse cycle, with louvered sides and with a certified cooling capacity of 20,000 Btu/h to 27,900 Btu/h13.8
5b. Without reverse cycle, with louvered sides and with a certified cooling capacity of 28,000 Btu/h or more13.2
6. Without reverse cycle, without louvered sides, and with a certified cooling capacity less than 6,000 Btu/h12.8
7. Without reverse cycle, without louvered sides and with a certified cooling capacity of 6,000 to 7,900 Btu/h12.8
8a. Without reverse cycle, without louvered sides and with a certified cooling capacity of 8,000 to 10,900 Btu/h14.1
8b. Without reverse cycle, without louvered sides and with a certified cooling capacity of 11,000 to 13,900 Btu/h13.9
9. Without reverse cycle, without louvered sides and with a certified cooling capacity of 14,000 to 19,900 Btu/h13.7
10. Without reverse cycle, without louvered sides and with a certified cooling capacity of 20,000 Btu/h or more13.8
11. With reverse cycle, with louvered sides, and with a certified cooling capacity less than 20,000 Btu/h14.4
12. With reverse cycle, without louvered sides, and with a certified cooling capacity less than 14,000 Btu/h13.7
13. With reverse cycle, with louvered sides, and with a certified cooling capacity of 20,000 Btu/h or more13.7
14. With reverse cycle, without louvered sides, and with a certified cooling capacity of 14,000 Btu/h or more12.8
15. Casement-Only13.9
16. Casement-Slider15.3

1 The certified cooling capacity is determined by the manufacturer in accordance with 10 CFR 429.15(a)(3).

(c) Central air conditioners and heat pumps. The energy conservation standards defined in terms of the heating seasonal performance factor are based on Region IV, the minimum standardized design heating requirement, and the provisions of 10 CFR 429.16.

(1) Central air conditioners and central air conditioning heat pumps manufactured on or after January 1, 2015, and before January 1, 2023, must have Seasonal Energy Efficiency Ratio and Heating Seasonal Performance Factor not less than:

Product classSeasonal
energy
efficiency ratio
(SEER)
Heating
seasonal
performance
factor (HSPF)
(i) Split systems—air conditioners13
(ii) Split systems—heat pumps148.2
(iii) Single package units—air conditioners14
(iv) Single package units—heat pumps148.0
(v) Small-duct, high-velocity systems127.2
(vi)(A) Space-constrained products—air conditioners12
(vi)(B) Space-constrained products—heat pumps127.4

(2) In addition to meeting the applicable requirements in paragraph (c)(1) of this section, products in product class (i) of paragraph (c)(1) of this section (i.e., split-systems—air conditioners) that are installed on or after January 1, 2015, and before January 1, 2023, in the States of Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, South Carolina, Tennessee, Texas, or Virginia, or in the District of Columbia, must have a Seasonal Energy Efficiency Ratio (SEER) of 14 or higher. Any outdoor unit model that has a certified combination with a rating below 14 SEER cannot be installed in these States. The least efficient combination of each basic model must comply with this standard.

(3)(i) In addition to meeting the applicable requirements in paragraph (c)(1) of this section, products in product classes (i) and (iii) of paragraph (c)(1) of this section (i.e., split systems—air conditioners and single-package units—air conditioners) that are installed on or after January 1, 2015, and before January 1, 2023, in the States of Arizona, California, Nevada, or New Mexico must have a Seasonal Energy Efficiency Ratio (SEER) of 14 or higher and have an Energy Efficiency Ratio (EER) (at a standard rating of 95 °F dry bulb outdoor temperature) not less than the following:

Product classEnergy
efficiency ratio (EER)
(i) Split systems—air conditioners with rated cooling capacity less than 45,000 Btu/hr12.2
(ii) Split systems—air conditioners with rated cooling capacity equal to or greater than 45,000 Btu/hr11.7
(iii) Single-package units—air conditioners11.0

(ii) Any outdoor unit model that has a certified combination with a rating below 14 SEER or the applicable EER cannot be installed in this region. The least-efficient combination of each basic model must comply with this standard.

(4) Each basic model of single-package central air conditioners and central air conditioning heat pumps and each individual combination of split-system central air conditioners and central air conditioning heat pumps manufactured on or after January 1, 2015, shall have an average off mode electrical power consumption not more than the following:

Product classAverage off mode power
consumption PW,OFF
(watts)
(i) Split-system air conditioners30
(ii) Split-system heat pumps33
(iii) Single-package air conditioners30
(iv) Single-package heat pumps33
(v) Small-duct, high-velocity systems30
(vi) Space-constrained air conditioners30
(vii) Space-constrained heat pumps33

(5) Central air conditioners and central air conditioning heat pumps manufactured on or after January 1, 2023, must have a Seasonal Energy Efficiency Ratio 2 and a Heating Seasonal Performance Factor 2 not less than:

Product classSeasonal
energy
efficiency
ratio 2 (SEER2)
Heating
seasonal
performance
factor 2 (HSPF2)
(i)(A) Split systems—air conditioners with a certified cooling capacity less than 45,000 Btu/hr13.4
(i)(B) Split systems—air conditioners with a certified cooling capacity equal to or greater than 45,000 Btu/hr13.4
(ii) Split systems—heat pumps14.37.5
(iii) Single-package units—air conditioners13.4
(iv) Single-package units—heat pumps13.46.7
(v) Small-duct, high-velocity systems126.1
(vi)(A) Space-constrained products—air conditioners11.7
(vi)(B) Space-constrained products—heat pumps11.96.3

(6)(i) In addition to meeting the applicable requirements in paragraph (c)(5) of this section, products in product classes (i) and (iii) of paragraph (c)(5) of this section (i.e., split systems—air conditioners and single-package units—air conditioners) that are installed on or after January 1, 2023, in the southeast or southwest must have a Seasonal Energy Efficiency Ratio 2 and a Energy Efficiency Ratio 2 not less than:

Product classSoutheast *Southwest **
SEER2SEER2EER2 ***
(i)(A) Split-systems—air conditioners with a certified cooling capacity less than 45,000 Btu/hr14.314.311.7/9.8 †
(i)(B) Split-systems—air conditioners with a certified cooling capacity equal to or greater than 45,000 Btu/hr13.813.811.2/9.8 ††
(iii) Single-package units—air conditioners10.6

* “Southeast” includes the States of Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, Puerto Rico, South Carolina, Tennessee, Texas, Virginia, the District of Columbia, and the U.S. Territories.

** “Southwest” includes the States of Arizona, California, Nevada, and New Mexico.

*** EER refers to the energy efficiency ratio at a standard rating of 95 °F dry bulb outdoor temperature.

† The 11.7 EER2 standard applies to products with a certified SEER2 less than 15.2. The 9.8 EER2 standard applies to products with a certified SEER2 greater than or equal to 15.2.

†† The 11.2 EER2 standard applies to products with a certified SEER2 less than 15.2. The 9.8 EER2 standard applies to products with a certified SEER2 greater than or equal to 15.2.

(ii) Any model of outdoor unit that has a certified combination with a rating below the applicable standard level(s) for a region cannot be installed in that region. The least-efficient combination of each basic model, which for single-split-system air conditioner (AC) with single-stage or two-stage compressor (including space-constrained and small-duct high velocity systems (SDHV)) must be a coil-only combination, must comply with the applicable standard. See 10 CFR 429.16(a)(1) and (a)(4)(i).

(d) Water heaters. The uniform energy factor of water heaters shall not be less than the following:

Product classRated storage volume
and input rating
(if applicable)
Draw patternUniform energy factor
Gas-fired Storage Water Heater?20 gal and ?55 galVery Small0.3456 ? (0.0020 × Vr)
Low0.5982 ? (0.0019 × Vr)
Medium0.6483 ? (0.0017 × Vr)
High0.6920 ? (0.0013 × Vr)
>55 gal and ?100 galVery Small0.6470 ? (0.0006 × Vr)
Low0.7689 ? (0.0005 × Vr)
Medium0.7897 ? (0.0004 × Vr)
High0.8072 ? (0.0003 × Vr)
Oil-fired Storage Water Heater?50 galVery Small0.2509 ? (0.0012 × Vr)
Low0.5330 ? (0.0016 × Vr)
Medium0.6078 ? (0.0016 × Vr)
High0.6815 ? (0.0014 × Vr)
Electric Storage Water Heaters?20 gal and ?55 galVery Small0.8808 ? (0.0008 × Vr)
Low0.9254 ? (0.0003 × Vr)
Medium0.9307 ? (0.0002 × Vr)
High0.9349 ? (0.0001 × Vr)
>55 gal and ?120 galVery Small1.9236 ? (0.0011 × Vr)
Low2.0440 ? (0.0011 × Vr)
Medium2.1171 ? (0.0011 × Vr)
High2.2418 ? (0.0011 × Vr)
Tabletop Water Heater?20 gal and ?120 galVery Small0.6323 ? (0.0058 × Vr)
Low0.9188 ? (0.0031 × Vr)
Medium0.9577 ? (0.0023 × Vr)
High0.9884 ? (0.0016 × Vr)
Instantaneous Gas-fired Water Heater<2 gal and >50,000 Btu/hVery Small
Low
0.80
0.81
Medium0.81
High0.81
Instantaneous Electric Water Heater<2 galVery Small0.91
Low0.91
Medium0.91
High0.92
Grid-Enabled Water Heater>75 galVery Small1.0136 ? (0.0028 × Vr)
Low0.9984 ? (0.0014 × Vr)
Medium0.9853 ? (0.0010 × Vr)
High0.9720 ? (0.0007 × Vr)

* Vr is the Rated Storage Volume (in gallons), as determined pursuant to 10 CFR 429.17.

(e) Furnaces and boilers—(1) Furnaces. (i) The Annual Fuel Utilization Efficiency (AFUE) of residential furnaces shall not be less than the following for non-weatherized gas furnaces manufactured before November 19, 2015, non-weatherized oil furnaces manufactured before May 1, 2013, and weatherized furnaces manufactured before January 1, 2015:

Product classAFUE
(percent) 1
(A) Furnaces (excluding classes noted below)78
(B) Mobile Home furnaces75
(C) Small furnaces (other than those designed solely for installation in mobile homes) having an input rate of less than 45,000 Btu/hr
(1) Weatherized (outdoor)78
(2) Non-weatherized (indoor)78

1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) of this part.

(ii) The AFUE of residential furnaces shall not be less than the following starting on the compliance date indicated in the table below:

Product classAFUE
(percent) 1
Compliance date
(A) Non-weatherized gas furnaces (not including mobile home furnaces)80November 19, 2015.
(B) Mobile Home gas furnaces80November 19, 2015.
(C) Non-weatherized oil-fired furnaces (not including mobile home furnaces)83May 1, 2013.
(D) Mobile Home oil-fired furnaces75September 1, 1990.
(E) Weatherized gas furnaces81January 1, 2015.
(F) Weatherized oil-fired furnaces78January 1, 1992.
(G) Electric furnaces78January 1, 1992.

1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) of this part.

(iii) Furnaces manufactured on or after May 1, 2013, shall have an electrical standby mode power consumption (PW,SB) and electrical off mode power consumption (PW,OFF) not more than the following:

Product classMaximum standby mode electrical power consumption, PW,SB (watts)Maximum off mode electrical power consumption, PW,OFF (watts)
(A) Non-weatherized oil-fired furnaces (including mobile home furnaces)1111
(B) Electric furnaces1010

(2) Boilers. (i) The AFUE of residential boilers manufactured before September 1, 2012, shall not be less than the following:

Product classAFUE 1 (percent)
(A) Boilers (excluding gas steam)80
(B) Gas steam boilers75

1 Annual Fuel Utilization Efficiency, as determined in § 430.22(n)(2) of this part.

(ii) Except as provided in paragraph (e)(2)(iv) of this section, the AFUE of residential boilers, manufactured on or after September 1, 2012, and before January 15, 2021, shall not be less than the following and must comply with the design requirements as follows:

Product classAFUE 1
(percent)
Design requirements
(A) Gas-fired hot water boiler82Constant burning pilot not permitted.
Automatic means for adjusting water temperature required (except for boilers equipped with tankless domestic water heating coils).
(B) Gas-fired steam boiler80Constant burning pilot not permitted.
(C) Oil-fired hot water boiler84Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils).
(D) Oil-fired steam boiler82None.
(E) Electric hot water boilerNoneAutomatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils).

1 Annual Fuel Utilization Efficiency, as determined in § 430.22(n)(2) of this part.

(iii)(A) Except as provided in paragraph (e)(2)(v) of this section, the AFUE of residential boilers, manufactured on and after January 15, 2021, shall not be less than the following and must comply with the design requirements as follows:

Product classAFUE 1
(percent)
Design requirements
(1) Gas-fired hot water boiler84Constant-burning pilot not permitted. Automatic means for adjusting water temperature required (except for boilers equipped with tankless domestic water heating coils).
(2) Gas-fired steam boiler82Constant-burning pilot not permitted.
(3) Oil-fired hot water boiler86Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils).
(4) Oil-fired steam boiler85None.
(5) Electric hot water boilerNoneAutomatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils).
(6) Electric steam boilerNoneNone.

1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) of this part.

(B) Except as provided in paragraph (e)(2)(v) of this section, the standby mode power consumption (PW,SB) and off mode power consumption (PW,OFF) of residential boilers, manufactured on and after January 15, 2021, shall not be more than the following:

Product classPW,SB
(watts)
PW,OFF
(watts)
(1) Gas-fired hot water boiler99
(2) Gas-fired steam boiler88
(3) Oil-fired hot water boiler1111
(4) Oil-fired steam boiler1111
(5) Electric hot water boiler88
(6) Electric steam boiler88

(iv) Automatic means for adjusting water temperature. (A) The automatic means for adjusting water temperature as required under paragraph (e)(2)(ii) of this section must automatically adjust the temperature of the water supplied by the boiler to ensure that an incremental change in inferred heat load produces a corresponding incremental change in the temperature of water supplied.

(B) For boilers that fire at a single input rate, the automatic means for adjusting water temperature requirement may be satisfied by providing an automatic means that allows the burner or heating element to fire only when the means has determined that the inferred heat load cannot be met by the residual heat of the water in the system.

(C) When there is no inferred heat load with respect to a hot water boiler, the automatic means described in this paragraph shall limit the temperature of the water in the boiler to not more than 140 degrees Fahrenheit.

(D) A boiler for which an automatic means for adjusting water temperature is required shall be operable only when the automatic means is installed.

(v) A boiler that is manufactured to operate without any need for electricity or any electric connection, electric gauges, electric pumps, electric wires, or electric devices is not required to meet the AFUE or design requirements applicable to the boiler requirements of paragraph (e)(2)(ii) of this section, but must meet the requirements of paragraph (e)(2)(i) of this section, as applicable.

(f) Dishwashers. (1) All dishwashers manufactured on or after May 30, 2013, shall meet the following standard—

(i) Standard size dishwashers shall not exceed 307 kwh/year and 5.0 gallons per cycle. Standard size dishwashers have a capacity equal to or greater than eight place settings plus six serving pieces as specified in AHAM DW-1-2020 (incorporated by reference, see § 430.3) using the test load specified in section 2.3 of appendix C1 or section 2.4 of appendix C2 in subpart B of this part, as applicable.

(ii) Compact size dishwashers shall not exceed 222 kwh/year and 3.5 gallons per cycle. Compact size dishwashers have a capacity less than eight place settings plus six serving pieces as specified in AHAM DW-1-2020 (incorporated by reference, see § 430.3) using the test load specified in section 2.3 of appendix C1 or section 2.4 of appendix C2 in subpart B of this part, as applicable.

(2) [Reserved]

(g) Clothes washers. (1) Clothes washers manufactured on or after January 1, 2007 shall have a Modified Energy Factor no less than:

Product classModified energy factor
(cu.ft./kWh/cycle)
i. Top-loading, Compact (less than 1.6 ft3 capacity)0.65.
ii. Top-loading, Standard (1.6 ft3 or greater capacity)1.26.
iii. Top-Loading, Semi-AutomaticNot Applicable.1
iv. Front-loading1.26.
v. Suds-savingNot Applicable.1

1 Must have an unheated rinse water option.

(2) All top-loading or front-loading standard-size residential clothes washers manufactured on or after January 1, 2011, and before March 7, 2015, shall meet the following standard—

(i) A Modified Energy Factor of at least 1.26; and

(ii) A Water Factor of not more than 9.5.

(3) Clothes washers manufactured on or after March 7, 2015, and before January 1, 2018, shall have an Integrated Modified Energy Factor no less than, and an Integrated Water Factor no greater than:

Product classIntegrated modified energy factor
(cu.ft./kWh/cycle)
Integrated water
factor
(gal/cycle/cu.ft.)
i. Top-loading, Compact (less than 1.6 ft3 capacity)0.8614.4
ii. Top-loading, Standard (1.6 ft3 or greater capacity)1.298.4
iii. Front-loading, Compact (less than 1.6 ft3 capacity)1.138.3
iv. Front-loading, Standard (1.6 ft3 or greater capacity)1.844.7

(4) Clothes washers manufactured on or after January 1, 2018, shall have an Integrated Modified Energy Factor no less than, and an Integrated Water Factor no greater than:

Product classIntegrated modified
energy factor
(cu.ft./kWh/cycle)
Integrated water factor
(gal/cycle/cu.ft.)
(i) Top-loading, Compact (less than 1.6 ft 3 capacity)1.1512.0
(ii) Top-loading, Standard (1.6 ft 3 or greater capacity)1.576.5
(iii) Front-loading, Compact (less than 1.6 ft 3 capacity)1.138.3
(iv) Front-loading, Standard (1.6 ft 3 or greater capacity)1.844.7

(h) Clothes dryers. (1) Gas clothes dryers manufactured after January 1, 1988 shall not be equipped with a constant burning pilot.

(2) Clothes dryers manufactured on or after May 14, 1994 and before January 1, 2015, shall have an energy factor no less than:

Product classEnergy
factor
(lbs/kWh)
i. Electric, Standard (4.4 ft3 or greater capacity)3.01
ii. Electric, Compact (120V) (less than 4.4 ft3 capacity)3.13
iii. Electric, Compact (240V) (less than 4.4 ft3 capacity)2.90
iv. Gas2.67

(3) Clothes dryers manufactured on or after January 1, 2015, shall have a combined energy factor no less than:

Product classCombined energy factor
(lbs/kWh)
(i) Vented Electric, Standard (4.4 ft 3 or greater capacity)3.73
(ii) Vented Electric, Compact (120V) (less than 4.4 ft 3 capacity)3.61
(iii) Vented Electric, Compact (240V) (less than 4.4 ft 3 capacity)3.27
(iv) Vented Gas3.30
(v) Ventless Electric, Compact (240V) (less than 4.4 ft 3 capacity)2.55
(vi) Ventless Electric, Combination Washer-Dryer2.08

(i) Direct heating equipment. (1) Vented home heating equipment manufactured on or after January 1, 1990 and before April 16, 2013, shall have an annual fuel utilization efficiency no less than:

Product classAnnual fuel utilization efficiency, Jan. 1, 1990 (percent)
1. Gas wall fan type up to 42,000 Btu/h73
2. Gas wall fan type over 42,000 Btu/h74
3. Gas wall gravity type up to 10,000 Btu/h59
4. Gas wall gravity type over 10,000 Btu/h up to 12, 000 Btu/h60
5. Gas wall gravity type over 12,000 Btu/h up to 15,000 Btu/h61
6. Gas wall gravity type over 15,000 Btu/h up to 19,000 Btu/h62
7. Gas wall gravity type over 19,000 Btu/h and up to 27,000 Btu/h63
8. Gas wall gravity type over 27,000 Btu/h and up to 46,000 Btu/h64
9. Gas wall gravity type over 46,000 Btu/h65
10. Gas floor up to 37,000 Btu/h56
11. Gas floor over 37,000 Btu/h57
12. Gas room up to 18,000 Btu/h57
13. Gas room over 18,000 Btu/h up to 20,000 Btu/h58
14. Gas room over 20,000 Btu/h up to 27,000 Btu/h63
15. Gas room over 27,000 Btu/h up to 46,000 Btu/h64
16. Gas room over 46,000 Btu/h65

(2) Vented home heating equipment manufactured on or after April 16, 2013, shall have an annual fuel utilization efficiency no less than:

Product classAnnual fuel utilization efficiency, April 16, 2013 (percent)
Gas wall fan type up to 42,000 Btu/h75
Gas wall fan type over 42,000 Btu/h76
Gas wall gravity type up to 27,000 Btu/h65
Gas wall gravity type over 27,000 Btu/h up to 46,000 Btu/h66
Gas wall gravity type over 46,000 Btu/h67
Gas floor up to 37,000 Btu/h57
Gas floor over 37,000 Btu/h58
Gas room up to 20,000 Btu/h61
Gas room over 20,000 Btu/h up to 27,000 Btu/h66
Gas room over 27,000 Btu/h up to 46,000 Btu/h67
Gas room over 46,000 Btu/h68

(j) Cooking Products (1) Gas cooking products with an electrical supply cord manufactured on or after January 1, 1990, shall not be equipped with a constant burning pilot light.

(2) Gas cooking products without an electrical supply cord manufactured on or after April 9, 2012, shall not be equipped with a constant burning pilot light.

(3) Microwave ovens:

(i) Microwave-only ovens and countertop convection microwave ovens manufactured on or after June 17, 2016, and before June 22, 2026, shall have an average standby power not more than 1.0 watt. Built-in and over-the-range convection microwave ovens manufactured on or after June 17, 2016, and before June 22, 2026, shall have an average standby power not more than 2.2 watts.

(ii) Microwave-only ovens and countertop convection microwave ovens manufactured on or after June 22, 2026, shall have an average standby power not more than 0.6 watts. Built-in and over-the-range convection microwave ovens manufactured on or after June 22, 2026, shall have an average standby power not more than 1.0 watt.

(k) Pool heaters. (1) Gas-fired pool heaters manufactured on and after April 16, 2013 and before May 30, 2028, shall have a thermal efficiency not less than 82%.

(2) Gas-fired pool heaters and electric pool heaters manufactured on and after May 30, 2028, shall have an integrated thermal efficiency not less than the following:

where QIN is the certified input capacity of a gas-fired pool heater basic model, in Btu/h, and PE is the certified active electrical power of an electric pool heater, in Btu/h.

(l) Television sets. [Reserved]

(m) Fluorescent lamp ballasts—(1) Standards for fluorescent lamp ballasts (other than dimming ballasts). Except as provided in paragraphs (m)(2) and (3) of this section, each fluorescent lamp ballast manufactured on or after November 14, 2014,

(i) Designed and marketed—

(A) To operate at nominal input voltages at or between 120 and 277 volts;

(B) To operate with an input current frequency of 60 Hertz; and

(C) For use in connection with fluorescent lamps (as defined in § 430.2)

(ii) Must have—

(A) A power factor of:

(1) 0.9 or greater for ballasts that are not residential ballasts; or

(2) 0.5 or greater for residential ballasts; and

(B) A ballast luminous efficiency not less than the following:

BLE = A/(1 + B × average total lamp arc power ^ ?C) Where A, B, and C are as follows:
DescriptionABC
Instant start and rapid start ballasts (not classified as residential ballasts) that are designed and marketed to operate:
4-foot medium bipin lamps;0.9930.270.25
2-foot U-shaped lamps; or
8-foot slimline lamps.
Programmed start ballasts (not classified as residential ballasts) that are designed and marketed to operate:
4-foot medium bipin lamps;0.9930.510.37
2-foot U-shaped lamps;
4-foot miniature bipin standard output lamps; or
4-foot miniature bipin high output lamps.
Instant start and rapid start ballasts (not classified as sign ballasts) that are designed and marketed to operate 8-foot high output lamps0.9930.380.25
Programmed start ballasts (not classified as sign ballasts) that are designed and marketed to operate 8-foot high output lamps0.9730.700.37
Sign ballasts that are designed and marketed to operate 8-foot high output lamps0.9930.470.25
Instant start and rapid start residential ballasts that are designed and marketed to operate:
4-foot medium bipin lamps;0.9930.410.25
2-foot U-shaped lamps; or
8-foot slimline lamps.
Programmed start residential ballasts that are designed and marketed to operate:
4-foot medium bipin lamps or0.9730.710.37
2-foot U-shaped lamps.

(2) Standards for certain dimming ballasts. Except as provided in paragraph (m)(3) of this section, each dimming ballast manufactured on or after November 14, 2014; designed and marketed to operate one F34T12, two F34T12, two F96T12/ES, or two F96T12HO/ES lamps; and

(i) Designed and marketed—

(A) To operate at nominal input voltages at or between 120 and 277 volts;

(B) To operate with an input current frequency of 60 Hertz; and

(C) For use in connection with fluorescent lamps (as defined in § 430.2)

(ii) Must have—

(A) A power factor of:

(1) 0.9 or greater for ballasts that are not residential ballasts; or

(2) 0.5 or greater for residential ballasts; and

(B) A ballast luminous efficiency not less than the following:

Designed and marketed for operation of a maximum ofNominal input
voltage
Total nominal lamp wattsBallast luminous efficiency
Low frequency ballastsHigh frequency ballasts
One F34T12 lamp120/277340.7770.778
Two F34T12 lamps120/277680.8040.805
Two F96T12/ES lamps120/2771200.8760.884
Two F96T12HO/ES lamps120/2771900.7110.713

(3) Exemptions. The power factor and ballast luminous efficiency standards described in paragraph (m)(1)(ii) and (m)(2)(ii) of this section do not apply to:

(i) A dimming ballast designed and marketed to operate exclusively lamp types other than one F34T12, two F34T12, two F96T12/ES, or two F96T12HO/ES lamps;

(ii) A low frequency ballast that is designed and marketed to operate T8 diameter lamps; is designed and marketed for use in electromagnetic-interference-sensitive-environments only; and is shipped by the manufacturer in packages containing 10 or fewer ballasts; or

(iii) A programmed start ballast that operates 4-foot medium bipin T8 lamps and delivers on average less than 140 milliamperes to each lamp.

(4) For the purposes of this paragraph (m), the definitions found in appendix Q of subpart B of this part apply.

(n) General service fluorescent lamps and incandescent reflector lamps. (1) Each of the following general service fluorescent lamps manufactured after the effective dates specified in the table must meet or exceed the following color rendering index standards:

Lamp typeNominal lamp watts *Minimum color rendering indexEffective date
(i) 4-foot medium bipin>35 W
?35 W
69
45
Nov. 1, 1995.
Nov. 1, 1995.
(ii) 2-foot U-shaped>35 W
?35 W
69
45
Nov. 1, 1995.
Nov. 1, 1995.
(iii) 8-foot slimline>65 W
?65 W
69
45
May 1, 1994.
May 1, 1994.
(iv) 8-foot high output>100 W
?100 W
69
45
May 1, 1994.
May 1, 1994.

* Nominal lamp watts means the wattage at which a fluorescent lamp is designed to operate. 42 U.S.C. § 6291(29)(H)

(2) The standards described in paragraph (n)(1) of this section do not apply to:

(i) Any 4-foot medium bipin lamp or 2-foot U-shaped lamp with a rated wattage less than 28 watts;

(ii) Any 8-foot high output lamp not defined in ANSI C78.81-2010 (incorporated by reference; see § 430.3) or related supplements, or not 0.800 nominal amperes; or

(iii) Any 8-foot slimline lamp not defined in ANSI C78.3 (incorporated by reference; see § 430.3).

(3) Each of the following general service fluorescent lamps manufactured on or after January 26, 2018, must meet or exceed the following lamp efficacy standards shown in the table:

Lamp typeCorrelated color
temperature
Minimum
average lamp
efficacy
lm/W
(i) 4-foot medium bipin lamps (straight-shaped lamp with medium bipin base, nominal overall length of 48 inches, and rated wattage of 25 or more)?4,500K
>4,500K and ?7,000K
92.4
88.7
(ii) 2-foot U-shaped lamps (U-shaped lamp with medium bipin base, nominal overall length between 22 and 25 inches, and rated wattage of 25 or more)?4,500K
>4,500K and ?7,000K
85.0
83.3
(iii) 8-foot slimline lamps (instant start lamp with single pin base, nominal overall length of 96 inches, and rated wattage of 49 or more)?4,500K
>4,500K and ?7,000K
97.0
93.0
(iv) 8-foot high output lamps (rapid start lamp with recessed double contact base, nominal overall length of 96 inches)?4,500K
>4,500K and ?7,000K
92.0
88.0
(v) 4-foot miniature bipin standard output lamps (straight-shaped lamp with miniature bipin base, nominal overall length between 45 and 48 inches, and rated wattage of 25 or more)?4,500K
>4,500K and ?7,000K
95.0
89.3
(vi) 4-foot miniature bipin high output lamps (straight-shaped lamp with miniature bipin base, nominal overall length between 45 and 48 inches, and rated wattage of 44 or more)?4,500K
>4,500K and ?7,000K
82.7
76.9
Note 1 to paragraph (n)(3):

For paragraphs (n)(3)(i) through (vi), rated wattage is defined with respect to fluorescent lamps and general service fluorescent lamps in § 430.2.

(4) Subject to the sales prohibition in paragraph (dd) of this section, each of the following incandescent reflector lamps manufactured after July 14, 2012, must meet or exceed the lamp efficacy standards shown in the table:

Rated wattageLamp spectrumLamp diameter inchesRated voltage of lampMinimum
average lamp
efficacy
lm/W
(i) 40-205Standard Spectrum>2.5?125 V
<125 V
6.8*P0.27
5.9*P0.27
?2.5?125 V
<125 V
5.7*P0.27
5.0*P0.27
(ii) 40-205Modified Spectrum>2.5?125 V
<125 V
5.8*P0.27
5.0*P0.27
?2.5?125 V
<125 V
4.9*P0.27
4.2*P0.27
Note 2 to paragraph (n)(4):

P is equal to the rated wattage, in watts. Rated wattage is defined with respect to incandescent reflector lamps in § 430.2.

Note 3 to paragraph (n)(4):

Standard Spectrum means any incandescent reflector lamp that does not meet the definition of modified spectrum in § 430.2.

(5) The standards specified in this section do not apply to the following types of incandescent reflector lamps:

(i) Lamps rated at 50 watts or less that are ER30, BR30, BR40, or ER40 lamps;

(ii) Lamps rated at 65 watts that are BR30, BR40, or ER40 lamps; or

(iii) R20 incandescent reflector lamps rated 45 watts or less.

(o) Faucets. The maximum water use allowed for any of the following faucets manufactured after January 1, 1994, when measured at a flowing water pressure of 60 pounds per square inch (414 kilopascals), shall be as follows:

Faucet typeMaximum flow rate
(gpm (L/min)) or (gal/cycle (L/cycle))
Lavatory faucets2.2 gpm (8.3 L/min) 1 2
Lavatory replacement aerators2.2 gpm (8.3 L/min)
Kitchen faucets2.2 gpm (8.3 L/min)
Kitchen replacement aerators2.2 gpm (8.3 L/min)
Metering faucets0.25 gal/cycle (0.95 L/cycle) 3 4

Note:

1 Sprayheads with independently-controlled orifices and manual controls.

The maximum flow rate of each orifice that manually turns on or off shall not exceed the maximum flow rate for a lavatory faucet.

2 Sprayheads with collectively controlled orifices and manual controls.

The maximum flow rate of a sprayhead that manually turns on or off shall be the product of (a) the maximum flow rate for a lavatory faucet and (b) the number of component lavatories (rim space of the lavatory in inches (millimeters) divided by 20 inches (508 millimeters)).

3 Sprayheads with independently controlled orifices and metered controls.

The maximum flow rate of each orifice that delivers a pre-set volume of water before gradually shutting itself off shall not exceed the maximum flow rate for a metering faucet.

4 Sprayheads with collectively-controlled orifices and metered controls.

The maximum flow rate of a sprayhead that delivers a pre-set volume of water before gradually shutting itself off shall be the product of (a) the maximum flow rate for a metering faucet and (b) the number of component lavatories (rim space of the lavatory in inches (millimeters) divided by 20 inches (508 millimeters)).

(p) Showerheads. The maximum water use allowed for any showerheads manufactured after January 1, 1994, shall be 2.5 gallons per minute (9.5 liters per minute) when measured at a flowing pressure of 80 pounds per square inch gage (552 kilopascals). When used as a component of any such showerhead, the flow-restricting insert shall be mechanically retained at the point of manufacture such that a force of 8.0 pounds force (36 Newtons) or more is required to remove the flow-restricting insert, except that this requirement shall not apply to showerheads for which removal of the flow-restricting insert would cause water to leak significantly from areas other than the spray face.

(q) Water closets. The maximum water use allowed in gallons per flush for any of the following water closets is as follows:

Water closet typeMaximum flush rate
(gpf (Lpf))
Manufactured after January 1, 1994Manufactured after January 1, 1997
(1) Gravity flush tank water closet1.6 (6.0)1.6 (6.0)
(2) Flushometer tank water closet1.6 (6.0)1.6 (6.0)
(3) Electromechanical hydraulic water closet1.6 (6.0)1.6 (6.0)
(4) Blowout bowl water closet3.5 (13.2)3.5 (13.2)
(5) Flushometer valve water closets, other than those with blowout bowls1.6 (6.0)

(r) Urinals. The maximum water use allowed for any urinals manufactured after January 1, 1994, shall be 1.0 gallons per flush (3.8 liters per flush). The maximum water use allowed for a trough-type urinal shall be the product of:

(1) The maximum flow rate for a urinal and

(2) The length of the trough-type urinal in inches (millimeter) divided by 16 inches (406 millimeters).

(s) Ceiling fans and ceiling fan light kits. (1) All ceiling fans manufactured on or after January 1, 2007, shall have the following features:

(i) Fan speed controls separate from any lighting controls;

(ii) Adjustable speed controls (either more than 1 speed or variable speed);

(iii) The capability of reversible fan action, except for—

(A) Fans sold for industrial applications;

(B) Fans sold for outdoor applications; and

(C) Cases in which safety standards would be violated by the use of the reversible mode.

(2)(i) Ceiling fans manufactured on or after January 21, 2020, shall meet the requirements shows in the table:

Product class as
defined in Appendix U
Minimum
efficiency
(CFM/W) 1
Very small-diameter (VSD)D ? 12 in.: 21.
D > 12 in.: 3.16 D-17.04.
Standard0.65 D + 38.03.
Hugger0.29 D + 34.46.
High-speed small-diameter (HSSD)4.16 D + 0.02.

1 D is the ceiling fan’s blade span, in inches, as determined in Appendix U of this part.

(ii) Large-diameter ceiling fans, as defined in appendix U to subpart B of this part, manufactured on or after January 21, 2020, shall have a CFEI greater than or equal to –

(A) 1.00 at high speed; and

(B) 1.31 at 40 percent speed or the nearest speed that is not less than 40 percent speed.

(iii) The provisions in this appendix apply to ceiling fans except:

(A) Ceiling fans where the plane of rotation of a ceiling fan’s blades is not less than or equal to 45 degrees from horizontal, or cannot be adjusted based on the manufacturer’s specifications to be less than or equal to 45 degrees from horizontal;

(B) Centrifugal ceiling fans, as defined in Appendix U of this part;

(C) Belt-driven ceiling fans, as defined in Appendix U of this part;

(D) Oscillating ceiling fans, as defined in Appendix U of this part; and

(E) Highly-decorative ceiling fans, as defined in Appendix U of this part.

(3) Ceiling fan light kits manufactured on or after January 1, 2007, and prior to January 21, 2020, with medium screw base sockets must be packaged with medium screw base lamps to fill all sockets. These medium screw base lamps must—

(i) Be compact fluorescent lamps that meet or exceed the following requirements or be as described in paragraph (s)(3)(ii) of this section:

FactorRequirements
Rated Wattage (Watts) & Configuration 1Minimum Initial Lamp Efficacy (lumens per watt) 2
Bare Lamp:
Lamp Power <1545.0
Lamp Power ?1560.0
Covered Lamp (no reflector):
Lamp Power <1540.0
15?Lamp Power <1948.0
19?Lamp Power <2550.0
Lamp Power ?2555.0
With Reflector:
Lamp Power <2033.0
Lamp Power ?2040.0
Lumen Maintenance at 1,000 hours? 90.0%
Lumen Maintenance at 40 Percent of Lifetime? 80.0%
Rapid Cycle Stress TestEach lamp must be cycled once for every 2 hours of lifetime. At least 5 lamps must meet or exceed the minimum number of cycles.
Lifetime? 6,000 hours for the sample of lamps.

1 Use rated wattage to determine the appropriate minimum efficacy requirements in this table.

2 Calculate efficacy using measured wattage, rather than rated wattage, and measured lumens to determine product compliance. Wattage and lumen values indicated on products or packaging may not be used in calculation.

(ii) Be light sources other than compact fluorescent lamps that have lumens per watt performance at least equivalent to comparably configured compact fluorescent lamps meeting the energy conservation standards in paragraph (s)(3)(i) of this section.

(4) Ceiling fan light kits manufactured on or after January 1, 2007, and prior January 21, 2020, with pin-based sockets for fluorescent lamps must use an electronic ballast and be packaged with lamps to fill all sockets. These lamp ballast platforms must meet the following requirements:

FactorRequirement
System Efficacy Per Lamp Ballast Platform in Lumens Per Watt (lm/w)?50 lm/w for all lamps below 30 total listed lamp watts.
?60 lm/w for all lamps that are ? 24 inches and
?30 total listed lamp watts.
?70 lm/w for all lamps that are > 24 inches and
?30 total listed lamp watts.

(5) Ceiling fan light kits manufactured on or after January 1, 2009, and prior to January 21, 2020, with socket types other than those covered in paragraph (s)(3) or (4) of this section, including candelabra screw base sockets, must be packaged with lamps to fill all sockets and must not be capable of operating with lamps that total more than 190 watts.

(6) Ceiling fan light kits manufactured on or after January 21, 2020 must be packaged with lamps to fill all sockets, and each basic model of lamp packaged with the basic model of CFLK, each basic model of consumer-replaceable SSL packaged with the basic model of CFLK, and each basic model of non-consumer-replaceable SSL in the CFLK basic model shall meet the requirements shown in paragraphs (s)(6)(i) and (ii) of this section:

Lumens 1Minimum required efficacy
(lm/W)
(i) <12050.
(ii) ?120(74.0?29.42 × 0.9983lumens).

1 Use the lumen output for each basic model of lamp packaged with the basic model of CFLK, each basic model of consumer-replaceable SSL packaged with the basic model of CFLK, or each basic model of non-consumer-replaceable SSL in the CFLK basic model to determine the applicable standard.

(i) Ceiling fan light kits with medium screw base sockets manufactured on or after January 21, 2020 and packaged with compact fluorescent lamps must include lamps that also meet the following requirements:

Lumen Maintenance at 1,000 hours?90.0%.
Lumen Maintenance at 40 Percent of Lifetime?80.0%.
Rapid Cycle Stress TestEach lamp must be cycled once for every 2 hours of lifetime of compact fluorescent lamp as defined in § 430.2. At least 5 lamps must meet or exceed the minimum number of cycles.
Lifetime?6,000 hours for the sample of lamps.

(ii) Ceiling fan light kits with pin based sockets for fluorescent lamps, manufactured on or after January 21, 2020, must also use an electronic ballast.

(t) Torchieres. A torchiere manufactured on or after January 1, 2006 shall:

(1) Consume not more than 190 watts of power; and

(2) Not be capable of operating with lamps that total more than 190 watts.

(u) Compact fluorescent lamps. (1) Medium Base Compact Fluorescent Lamps. Subject to the sales prohibition in paragraph (dd) of this section, a bare or covered (no reflector) medium base compact fluorescent lamp manufactured on or after January 1, 2006, must meet the following requirements:

FactorRequirements
Labeled Wattage (Watts) & Configuration *Measured initial lamp efficacy (lumens per watt) must be at least:
Bare Lamp:
Labeled Wattage < 1545.0.
Labeled Wattage ? 1560.0.
Covered Lamp (no reflector):
Labeled Wattage < 1540.0.
15 ? Labeled Wattage < 1948.0.
19 ? Labeled Wattage < 2550.0.
Labeled Wattage ? 2555.0.
Lumen Maintenance at 1,000 Hours?90.0%.
Lumen Maintenance at 40 Percent of Lifetime **?80.0%.
Rapid Cycle Stress TestEach lamp must be cycled once for every 2 hours of lifetime.** At least 5 lamps must meet or exceed the minimum number of cycles.
Lifetime **?6,000 hours.

* Use labeled wattage to determine the appropriate efficacy requirements in this table; do not use measured wattage for this purpose.

** Lifetime refers to lifetime of a compact fluorescent lamp as defined in 10 CFR 430.2.

(2) [Reserved].

(v) Dehumidifiers. (1) Dehumidifiers manufactured on or after October 1, 2012, shall have an energy factor that meets or exceeds the following values:

Product capacity (pints/day)Minimum energy factor (liters/kWh)
Up to 35.001.35
35.01-45.001.50
45.01-54.001.60
54.01-75.001.70
75.01 or more2.5

(2) Dehumidifiers manufactured on or after June 13, 2019, shall have an integrated energy factor that meets or exceeds the following values:

Portable dehumidifier product capacity
(pints/day)
Minimum
integrated
energy factor
(liters/kWh)
25.00 or less1.30
25.01-50.001.60
50.01 or more2.80
Whole-home dehumidifier product case volume (cubic feet)
8.0 or less1.77
More than 8.02.41

(w) External power supplies. (1)(i) Except as provided in paragraphs (w)(2) and (5) of this section, all class A external power supplies manufactured on or after July 1, 2008, shall meet the following standards:

Active mode
Nameplate outputRequired efficiency (decimal equivalent of a percentage)
Less than 1 watt0.5 times the Nameplate output.
From 1 watt to not more than 51 wattsThe sum of 0.09 times the Natural Logarithm of the Nameplate Output and 0.5.
Greater than 51 watts0.85.
No-load mode
Nameplate outputMaximum consumption
Not more than 250 watts0.5 watts.

(ii) Except as provided in paragraphs (w)(5), (w)(6), and (w)(7) of this section, all direct operation external power supplies manufactured on or after February 10, 2016, shall meet the following standards:

(iii) Except as provided in paragraphs (w)(5), (w)(6), and (w)(7) of this section, all external power supplies manufactured on or after February 10, 2016, shall meet the following standards:

Class A EPSNon-Class A EPS
Direct Operation EPSLevel VI: 10 CFR 430.32(w)(1)(ii)Level VI: 10 CFR 430.32(w)(1)(ii).
Indirect Operation EPSLevel IV: 10 CFR 430.32(w)(1)(i)No Standards.

(2) A basic model of external power supply is not subject to the energy conservation standards of paragraph (w)(1)(ii) of this section if the external power supply—

(i) Is manufactured during the period beginning on February 10, 2016, and ending on February 10, 2020;

(ii) Is marked in accordance with the External Power Supply International Efficiency Marking Protocol, as in effect on February 10, 2016;

(iii) Meets, where applicable, the standards under paragraph (w)(1)(i) of this section, and has been certified to the Secretary as meeting those standards; and

(iv) Is made available by the manufacturer only as a service part or a spare part for an end-use product that—

(A) Constitutes the primary load; and

(B) Was manufactured before February 10, 2016.

(3) The standards described in paragraph (w)(1) of this section shall not constitute an energy conservation standard for the separate end-use product to which the external power supply is connected.

(4) Any external power supply subject to the standards in paragraph (w)(1) of this section shall be clearly and permanently marked in accordance with the International Efficiency Marking Protocol for External Power Supplies (incorporated by reference; see § 430.3), published by the U.S. Department of Energy.

(5) Non-application of no-load mode requirements. The no-load mode energy efficiency standards established in paragraph (w)(1) of this section shall not apply to an external power supply that—

(i) Is an AC-to-AC external power supply;

(ii) Has a nameplate output of 20 watts or more;

(iii) Is certified to the Secretary as being designed to be connected to a security or life safety alarm or surveillance system component; and

(iv) On establishment within the External Power Supply International Efficiency Marking Protocol, as referenced in the “Energy Star Program Requirements for Single Voltage External Ac-Dc and Ac-Ac Power Supplies” (incorporated by reference, see § 430.3), published by the Environmental Protection Agency, of a distinguishing mark for products described in this clause, is permanently marked with the distinguishing mark.

(6) An external power supply shall not be subject to the standards in paragraph (w)(1) of this section if it is a device that requires Federal Food and Drug Administration (FDA) listing and approval as a medical device in accordance with section 513 of the Federal Food, Drug, and Cosmetic Act (21 U.S.C. § 360(c)).

(7) A direct operation, AC-DC external power supply with nameplate output voltage less than 3 volts and nameplate output current greater than or equal to 1,000 milliamps that charges the battery of a product that is fully or primarily motor operated shall not be subject to the standards in paragraph (w)(1)(ii) of this section.

(x) General service incandescent lamps, intermediate base incandescent lamps and candelabra base incandescent lamps. (1) Subject to the sales prohibition in paragraph (dd) of this section, the energy conservation standards in this paragraph apply to general service incandescent lamps.

(i) Intended for a general service or general illumination application (whether incandescent or not);

(ii) Has a medium screw base or any other screw base not defined in ANSI C81.61 (incorporated by reference; see § 430.3); and

(iii) Is capable of being operated at a voltage at least partially within the range of 110 to 130 volts.

(2) Subject to the sales prohibition in paragraph (dd) of this section, general service incandescent lamps manufactured after the effective dates specified in the tables below, except as described in paragraph (x)(3) of this section, must have a color rendering index greater than or equal to 80, a rated wattage no greater than, and a lifetime no less than the values shown in the table below:

General Service Incandescent Lamps

Lumen ranges *Maximum
rated
wattage
Minimum
lifetime **
(hrs)
Effective
date
(i) 1490-2600721,0001/1/2012
(ii) 1050-1489531,0001/1/2013
(iii) 750-1049431,0001/1/2014
(iv) 310-749291,0001/1/2014

* Use measured initial lumen output to determine the applicable lumen range.

** Use lifetime determined in accordance with 10 CFR 429.27 to determine compliance with this standard.

(3) Subject to the sales prohibition in paragraph (dd) of this section, modified spectrum general service incandescent lamps manufactured after the effective dates specified must have a color rendering index greater than or equal to 75, a rated wattage no greater than, and a lifetime no less than, the values shown in the table below:

Modified Spectrum General Service Incandescent Lamps

Lumen ranges *Maximum
rated
wattage
Minimum
lifetime **
(hrs)
Effective
date
(i) 1118-1950721,0001/1/2012
(ii) 788-1117531,0001/1/2013
(iii) 563-787431,0001/1/2014
(iv) 232-562291,0001/1/2014

* Use measured initial lumen output to determine the applicable lumen range.

** Use lifetime determined in accordance with 10 CFR 429.27 to determine compliance with this standard.

(4) Subject to the sales prohibition in paragraph (dd) of this section, each candelabra base incandescent lamp must not exceed 60 rated watts.

(5) Subject to the sales prohibition in paragraph (dd) of this section, each intermediate base incandescent lamp must not exceed 40 rated watts.

(y) Residential furnace fans. Residential furnace fans incorporated in the products listed in Table 1 of this paragraph and manufactured on and after July 3, 2019, shall have a fan energy rating (FER) value that meets or is less than the following values:

Table 1—Energy Conservation Standards for Covered Residential Furnace Fans*

Product classFER ** (Watts/1000 cfm)
Non-Weatherized, Non-Condensing Gas Furnace Fan (NWG-NC)FER = 0.044 × QMax + 182
Non-Weatherized, Condensing Gas Furnace Fan (NWG-C)FER = 0.044 × QMax + 195
Weatherized Non-Condensing Gas Furnace Fan (WG-NC)FER = 0.044 × QMax + 199
Non-Weatherized, Non-Condensing Oil Furnace Fan (NWO-NC)FER = 0.071 × QMax + 382
Non-Weatherized Electric Furnace/Modular Blower Fan (NWEF/NWMB)FER = 0.044 × QMax + 165
Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC)FER = 0.071 × QMax + 222
Mobile Home Non-Weatherized, Condensing Gas Furnace Fan (MH-NWG-C)FER = 0.071 × QMax + 240
Mobile Home Electric Furnace/Modular Blower Fan (MH-EF/MB)FER = 0.044 × QMax + 101
Mobile Home Non-Weatherized Oil Furnace Fan (MH-NWO)Reserved
Mobile Home Weatherized Gas Furnace Fan (MH-WG) **Reserved

* Furnace fans incorporated into hydronic air handlers, SDHV modular blowers, SDHV electric furnaces, and CAC/HP indoor units are not subject to the standards listed in this table.

** QMax is the airflow, in cfm, at the maximum airflow-control setting measured using the final DOE test procedure at 10 CFR part 430, subpart B, appendix AA.

(z) Battery chargers. (1) Battery chargers manufactured on or after June 13, 2018, must have a unit energy consumption (UEC) less than or equal to the prescribed “Maximum UEC” standard when using the equations for the appropriate product class and corresponding rated battery energy as shown in the following table:

Product classProduct class descriptionRated battery energy (Ebatt **)Special characteristic or battery voltageMaximum UEC (kWh/yr)
(as a function of Ebatt **)
1Low-Energy?5 WhInductive Connection *3.04
2Low-Energy, Low-Voltage<100 Wh<4 V0.1440 * Ebatt + 2.95
3Low-Energy, Medium-Voltage 4-10 VFor Ebatt <10 Wh,
1.42 kWh/y
Ebatt ?10 Wh,
0.0255 * Ebatt + 1.16
4Low-Energy, High-Voltage >10 V0.11 * Ebatt + 3.18
5Medium-Energy, Low-Voltage100-3000 Wh<20 V0.0257 * Ebatt + .815
6Medium-Energy, High-Voltage ?20 V0.0778 * Ebatt + 2.4
7High-Energy>3000 Wh0.0502 * Ebatt + 4.53

* Inductive connection and designed for use in a wet environment (e.g. electric toothbrushes).

** Ebatt = Rated battery energy as determined in 10 CFR part 429.39(a).

(2) A battery charger shall not be subject to the standards in paragraph (z)(1) of this section if it is a device that requires Federal Food and Drug Administration (FDA) listing and approval as a life-sustaining or life-supporting device in accordance with section 513 of the Federal Food, Drug, and Cosmetic Act (21 U.S.C. § 360(c)).

(3) All uninterruptible power supplies (UPS) manufactured on and after January 10, 2022, that utilize a NEMA 1-15P or 5-15P input plug and have an AC output shall have an average load adjusted efficiency that meets or exceeds the values shown in the table in this paragraph (z)(3) based on the rated output power (Prated) of the UPS.

Battery charger product classRated output powerMinimum efficiency
10a (VFD UPSs)0 W < Prated ? 300 W?1.20E-06 * P 2rated + 7.17E-04 * Prated + 0.862.
300 W < Prated ? 700 W?7.85E-08 * P 2rated + 1.01E-04 * Prated + 0.946.
Prated > 700 W?7.23E-09 * P 2rated + 7.52E-06 * Prated + 0.977.
10b (VI UPSs)0 W < Prated ? 300 W?1.20E-06 * P 2rated + 7.19E-04 * Prated + 0.863.
300 W < Prated ? 700 W?7.67E-08 * P 2rated + 1.05E-04 * Prated + 0.947.
Prated > 700 W?4.62E-09 * P 2rated + 8.54E-06 * Prated + 0.979.
10c (VFI UPSs)0 W < Prated ? 300 W?3.13E-06 * P 2rated + 1.96E-03 * Prated + 0.543.
300 W < Prated ? 700 W?2.60E-07 * P 2rated + 3.65E-04 * Prated + 0.764.
Prated > 700 W?1.70E-08 * P 2rated + 3.85E-05 * Prated + 0.876.

(aa) Miscellaneous refrigeration products. The energy standards as determined by the equations of the following table(s) shall be rounded off to the nearest kWh per year. If the equation calculation is halfway between the nearest two kWh per year values, the standard shall be rounded up to the higher of these values.

(1) Coolers manufactured starting on October 28, 2019 shall have Annual Energy Use (AEU) no more than:

Product classAEU (kWh/yr)
1. Built-in compact7.88AV + 155.8
2. Built-in
3. Freestanding compact
4. Freestanding

AV = Total adjusted volume, expressed in ft3, as calculated according to appendix A of subpart B of this part.

(2) Combination cooler refrigeration products manufactured starting on October 28, 2019 shall have Annual Energy Use (AEU) no more than:

Product classAEU (kWh/yr)
C-3A. Cooler with all-refrigerator—automatic defrost4.57AV + 130.4
C-3A-BI. Built-in cooler with all-refrigerator—automatic defrost5.19AV + 147.8
C-9. Cooler with upright freezers with automatic defrost without an automatic icemaker5.58AV + 147.7
C-9-BI. Built-in cooler with upright freezer with automatic defrost without an automatic icemaker6.38AV + 168.8
C-9I. Cooler with upright freezer with automatic defrost with an automatic icemaker5.58AV + 231.7
C-9I-BI. Built-in cooler with upright freezer with automatic defrost with an automatic icemaker6.38AV + 252.8
C-13A. Compact cooler with all-refrigerator—automatic defrost5.93AV + 193.7
C-13A-BI. Built-in compact cooler with all-refrigerator—automatic defrost6.52AV + 213.1

AV = Total adjusted volume, expressed in ft3, as calculated according to appendix A of subpart B of this part.

(bb) Rough service lamps and vibration service lamps. (1) Subject to the sales prohibition in paragraph (dd) of this section, rough service lamps manufactured on or after January 25, 2018 must:

(i) Have a shatter-proof coating or equivalent technology that is compliant with NSF/ANSI 51 (incorporated by reference; see § 430.3) and is designed to contain the glass if the glass envelope of the lamp is broken and to provide effective containment over the life of the lamp;

(ii) Have a rated wattage not greater than 40 watts; and

(iii) Be sold at retail only in a package containing one lamp.

(2) Subject to the sales prohibition in paragraph (dd) of this section, vibration service lamps manufactured on or after January 25, 2018 must:

(i) Have a rated wattage no greater than 40 watts; and

(ii) Be sold at retail only in a package containing one lamp.

(cc) Portable air conditioners. Single-duct portable air conditioners and dual-duct portable air conditioners manufactured on or after January 10, 2025 must have a combined energy efficiency ratio (CEER) in Btu/Wh no less than:

SACC: For single-speed portable air conditioners, SACC is seasonally adjusted cooling capacity in Btu/h, as determined in appendix CC of subpart B of this part. For variable-speed portable air conditioners, SACC shall be SACCFull in Btu/h, as determined in appendix CC of subpart B of this part.

(dd) General service lamp. Beginning July 25, 2022 the sale of any general service lamp that does not meet a minimum efficacy standard of 45 lumens per watt is prohibited.

(ee) Air cleaners. (1) Conventional room air cleaners as defined in § 430.2 with a PM2.5 clean air delivery rate (CADR) between 10 and 600 (both inclusive) cubic feet per minute (cfm) and manufactured on or after December 31, 2023, and before December 31, 2025, shall have an integrated energy factor (IEF) in PM2.5 CADR/W, as determined in § 430.23(hh)(4) that meets or exceeds the following values:

Product capacityIEF (PM2.5
CADR/W)
(i) 10 ?PM2.5 CADR <1001.7
(ii) 100 ?PM2.5 CADR <1501.9
(iii) PM2.5 CADR ?1502.0

(2) Conventional room air cleaners as defined in § 430.2 with a PM2.5 clean air delivery rate (CADR) between 10 and 600 (both inclusive) cubic feet per minute (cfm) and manufactured on or after December 31, 2025, shall have an integrated energy factor (IEF) in PM2.5 CADR/W, as determined in § 430.23(hh)(4) that meets or exceeds the following values:

Product capacityIEF (PM2.5
CADR/W)
(i) 10 ?PM2.5 CADR <1001.9
(ii) 100 ?PM2.5 CADR <1502.4
(iii) PM2.5 CADR ?1502.9