40 CFR 1036.530 – Test procedures for off-cycle testing
(a) General. This section describes the measurement and calculation procedures to perform field testing and determine whether tested engines and engine families meet emission standards under subpart E of this part. Calculate mass emission rates as specified in 40 CFR part 1065, subpart G. Use good engineering judgment to adapt these procedures for simulating vehicle operation in the laboratory.
(b) Vehicle preparation and measurement procedures. (1) Set up the vehicle for testing with a portable emissions measurement system (PEMS) as specified in 40 CFR part 1065, subpart J.
(2) Begin emission sampling and data collection as described in 40 CFR 1065.935(c)(3) before starting the engine at the beginning of the shift-day. Start the engine only after confirming that engine coolant temperature is at or below 40 °C.
(3) Measure emissions over one or more shift-days as specified in subpart E of this part.
(4) For engines subject to compression-ignition standards, record 1 Hz measurements of ambient temperature near the vehicle.
(c) Test Intervals. Determine the test intervals as follows:
(1) Spark-ignition. Create a single test interval that covers the entire shift-day for engines subject to spark-ignition standards. The test interval starts with the first pair of consecutive data points with no exclusions as described in paragraph (c)(3) of this section after the start of the shift-day and ends with the last pair of consecutive data points with no exclusions before the end of the shift day.
(2) Compression-ignition. Create a series of 300 second test intervals for engines subject to compression-ignition standards (moving-average windows) as follows:
(i) Begin and end each test interval with a pair of consecutive data points with no exclusions as described in paragraph (c)(3) of this section. Select the last data point of each test interval such that the test interval includes 300 seconds of data with no exclusions, as described in paragraph (d) of this section. The test interval may be a fraction of a second more or less than 300 seconds to account for the precision of the time stamp in recording 1 Hz data. A test interval may include up to 599 seconds of data with continuous exclusions; invalidate any test interval that includes at least 600 seconds of continuous sampling with excluded data.
(ii) The first 300 second test interval starts with the first pair of consecutive data points with no exclusions. Determine the start of each subsequent 300 second test interval by finding the first pair of consecutive data points with no exclusions after the initial data point of the previous test interval.
(iii) The last 300 second test interval ends with the last pair of consecutive data points with no exclusions before the end of the shift day.
(3) Excluded data. Exclude data from test intervals for any period meeting one or more of the following conditions:
(i) An analyzer or flow meter is performing zero and span drift checks or zero and span calibrations, including any time needed for the analyzer to stabilize afterward, consistent with good engineering judgment.
(ii) The engine is off, except as specified in § 1036.415(g).
(iii) The engine is performing an infrequent regeneration. Do not exclude data related to any other AECDs, except as specified in paragraph (c)(3)(vi) of this section.
(iv) The recorded ambient air temperature is below 5 °C or above the temperature calculated using the following equation.
(v) The vehicle is operating at an elevation more than 5,500 feet above sea level.
(vi) An engine has one or more active AECDs for emergency vehicles under § 1036.115(h)(4).
(vii) A single data point does not meet any of the conditions specified in paragraphs (c)(3)(i) through (vi) of this section, but it is preceded and followed by data points that both meet one or more of the specified exclusion conditions.
(d) Assembling test intervals. A test interval may include multiple subintervals separated by periods with one or more exclusions under paragraph (c)(3) of this section.
(1) Treat these test subintervals as continuous for calculating duration of the test interval for engines subject to compression-ignition standards.
(2) Calculate emission mass during each test subinterval and sum those subinterval emission masses to determine the emission mass over the test interval. Calculate emisson mass as described in 40 CFR 1065.650(c)(2)(i), with the following exceptions and clarifications:
(i) Correct NO
(ii) Disregard the provision in 40 CFR 1065.650(g) for setting negative emission mass to zero for test intervals and subintervals.
(iii) Calculation of emission mass in 40 CFR 1065.650 assumes a constant time interval, ?t. If it is not appropriate to assume ?t is constant for testing under this section, use good engineering judgment to record time at each data point and adjust the mass calculation from Eq. 1065.650-4 by treating ?t as a variable.
(e) Normalized CO
(f) Binning 300 second test intervals. For engines subject to compression-ignition standards, identify the appropriate bin for each of the 300 second test intervals based on its normalized CO
Table 1 to Paragraph (
Bin | Normalized CO |
---|---|
Bin 1 | |
Bin 2 |
(g) Off-cycle emissions quantities. Determine the off-cycle emissions quantities as follows:
(1) Spark-ignition. For engines subject to spark-ignition standards, the off cycle emission quantity, e
(2) Compression-ignition. For engines subject to compression-ignition standards, determine the off-cycle emission quantity for each bin. When calculating mean bin emissions from ten engines to apply the pass criteria for engine families in § 1036.425(c), set any negative off-cycle emissions quantity to zero before calculating mean bin emissions.
(i) Off-cycle emissions quantity for bin 1. The off-cycle emission quantity for bin 1, m
(ii) Off-cycle emissions quantity for bin 2. The off-cycle emission quantity for bin 2, e
e
(h) Shift-day ambient temperature. For engines subject to compression-ignition standards, determine the mean shift-day ambient temperature, T
(i) Graphical illustration. Figure 1 of this section illustrates a test interval with interruptions of one or more data points excluded under paragraph (c)(3) of this section. The x-axis is time and the y-axis is the mass emission rate at each data point, m