40 CFR 761.386 – Required experimental conditions for the validation study and subsequent use during decontamination
The following experimental conditions apply for any solvent:
(a) Temperature and pressure. Conduct the validation study and perform decontamination at room temperature (from ?15 °C to ?30 °C) and at atmospheric pressure.
(b) Agitation. Limit the movement in the solvent to the short-term movement from placing the contaminated surface into the soak solvent and from removing the surface from the soak solvent.
(c) Time of soak. Soak the surface for a minimum of 1 hour.
(d) Surface conditions for the validation study. Prior to beginning the validation study, ensure that there are no free-flowing liquids on surfaces and that surfaces are dry (i.e., there are no liquids visible without magnification). Also ensure that surfaces are virtually free from non-liquid residues, corrosion, and other defects which would prevent the solvent from freely circulating over the surface.
(e) Confirmatory sampling for the validation study. Select surface sample locations using representative sampling or a census. Sample a minimum area of 100 cm
(f) Concentration of PCBs. The method validated may be used only to decontaminate surfaces containing PCBs at concentrations on which the validation study was performed and lower concentrations.