(1) If electrical power at a panoramic irradiator is lost for longer than 10 seconds, the sources must return automatically to the shielded position.

Ask a legal question, get an answer ASAP!
Click here to chat with a lawyer about your rights.

    (2) The lock on the door of the radiation room of a panoramic irradiator must not be deactivated by a power failure.
    (3) During a power failure, the area around the pool of an irradiator shall not be entered without using an operable and calibrated radiation survey meter.
Rulemaking Authority Florida Statutes § 404.051(4). Law Implemented 404.051(1), (5), (6), 404.061, 404.081, 404.141 FS. History-New 8-14-96, Formerly 10D-91.1513.