(a) Every single-family residence shall have at least one smoke detector on every story of the dwelling unit.

(b) Every structure which:

Ask a legal question, get an answer ASAP!
Click here to chat with a lawyer about your rights.

Terms Used In Kansas Statutes 31-162

  • Contract: A legal written agreement that becomes binding when signed.
  • Dwelling unit: means a single-family residence, multiple-family residence and each living unit in a mixed-use building. See Kansas Statutes 31-161
  • Evidence: Information presented in testimony or in documents that is used to persuade the fact finder (judge or jury) to decide the case for one side or the other.
  • Manufactured home: means a structure which:

    (1) Is transportable in one or more sections which, in the traveling mode, is 8 body feet or more in width or 40 body feet or more in length, or, when erected on site, is 320 or more square feet, and which is built on a permanent chassis and designed to be used as a dwelling, with or without permanent foundation, when connected to the required utilities, and includes the plumbing, heating, air conditioning and electrical systems contained therein; and

    (2) is subject to the federal manufactured home construction and safety standards established pursuant to 42 U. See Kansas Statutes 77-201

  • Property: includes personal and real property. See Kansas Statutes 77-201
  • Residence: means the place which is adopted by a person as the person's place of habitation and to which, whenever the person is absent, the person has the intention of returning. See Kansas Statutes 77-201
  • Smoke detector: means a device or combination of devices which operate from a power supply in the dwelling unit or at the point of installation for the purpose of detecting visible or invisible particles of combustion. See Kansas Statutes 31-161

(1) Contains more than one dwelling unit; or

(2) contains at least one dwelling unit and is a mixed-use structure, shall contain at least one smoke detector at the uppermost ceiling of each interior stairwell and on every story in each dwelling unit.

(c) The owner of a structure shall supply and install all required smoke detectors. The owner of a structure shall test and maintain all smoke detectors, except inside rental units, the occupant shall test and maintain all smoke detectors after taking possession of the dwelling unit.

(d) The smoke detectors required in dwelling units in existence on January 1, 1999, may either be battery-powered or wired into the structure’s electrical system, and need not be interconnected. The smoke detectors required in dwelling units constructed after January 1, 1999, shall be wired permanently into the structure’s electrical system.

(e) For purposes of this act, manufactured homes as defined in Kan. Stat. Ann. § 58-4202, and amendments thereto, shall be subject to the federal, manufactured home construction and safety standards established pursuant to 42 U.S.C. § 5403 in lieu of the standards set forth herein. Owners and occupants of such manufactured homes shall be subject to the testing and maintenance standards for smoke detectors required under this act.

(f) Officials responsible for the enforcement of the smoke detector act shall not enter a dwelling unit solely for the purpose of determining compliance with the provisions of the smoke detector act except when:

(1) Conducting an inspection prior to the issuance of an occupancy permit or building permit;

(2) responding to a report of a fire in a dwelling unit, except in cases of a false alarm; or

(3) conducting, at the request of the owner or occupant, a home safety inspection.

(g) Evidence of the failure of any property owner to provide an operational smoke detector in a residence as required by this section shall not be admissible in any action for the purpose of determining any aspect of civil liability.

Evidence of the failure of any occupant to properly maintain a smoke detector as required by this section shall not be admissible in any action for the purpose of determining any aspect of civil liability.

(h) The provisions of the smoke detector act shall not constitute grounds for the purpose of offsetting, reducing or denying the payment of amounts due under any contract for or policy of insurance.